Model: 2101A
High-precision flux meter calibration instrument with touch screen operation and background light switching.
Tags: 0.005% Error, 20nWb~20Wb, Touch Screen
| Voltage Measurement Range | 1mV ~ 2V |
| Max Permissible Error | 2mV range: 0.01%; 200mV range: 0.005% |
| Pulse Width Range | 20us ~ 10s |
| Pulse Width Error | 0.5us |
| Flux Output Range | 20 nWb ~ 20 Wb |
Model: 1102A
4-channel synchronous voltage acquisition, static accuracy ≤±0.1%FS, supports external trigger.
Tags: 4-Channel Sync, 100kSps, ±0.1% Accuracy
| Channel Configuration | 4-channel synchronous acquisition |
| Sampling Rate | Up to 100kSps/channel |
| Accuracy | Static accuracy ≤±0.1%FS |
| Bandwidth | DC ~ 50kHz (-3dB) |
| Communication Interface | Ethernet, DB9 debug port |
Model: 1103A
16-channel micro-vibration sensor synchronous acquisition, supports LORA wireless transmission and Gigabit Ethernet.
Tags: 16-Channel, LORA Wireless, 250kS/s
| Channel Configuration | 16-channel synchronous acquisition |
| Sensor Type | 4-20mA two-wire current sensor |
| ADC Resolution | 16-bit |
| Sampling Rate | > 250kS/s |
| Trigger Mode | External Trigger (3.3V~6V) |
| Communication Interface | Gigabit Ethernet + 2x RS485 |
| Wireless Function | Supports LORA wireless transparent transmission |
| Power Supply | 18VDC |
Model: 1104A
FPGA-based 48-channel parallel acquisition, maximum sampling rate 1Msps.
Tags: 48-Channel, FPGA Architecture, 1Msps
| Channel Configuration | 48-channel synchronous acquisition |
| Core Architecture | FPGA multi-channel data acquisition |
| Input Signal | Voltage signal |
| Sampling Rate Range | 1sps ~ 1Msps |
| ADC Resolution | 16-bit |
| Communication Interface | RJ-45 Ethernet (100M/1000M) |
| Trigger Mode | Software Trigger |
| Working Power | +6V@2.5A, -6V@2A |
Model: 1201A
High-precision DC constant current output (1uA~100mA), suitable for metrology calibration and precision testing.
Tags: 1uA~100mA, 0.01nA Resolution, <5ppm Stability
| Output Range | 1μA ~ 100mA |
| Output Resolution | 0.01nA ~ 10nA |
| Setting Accuracy | ±(5ppm×RD+0.7nA) ~ ±(8ppm×RD+300nA) |
| Long-term Stability | <5ppm×RD+0.7nA |
| Programming Interface | USB Type-B, supports SCPI command set |
Model: 1201B
Desktop precision constant current source, balancing tiny signal excitation and conventional device testing.
Tags: Touch Screen, High Precision, Automation Integration
| Output Range | 1uA ~ 100mA |
| Display Mode | 4.3-inch color touch screen |
| Setting Accuracy | ±(5ppm×RD+0.7nA) to ±(8ppm×RD+300nA) |
| Programming Interface | USB Type-B, supports SCPI command set |
Model: 1202A
Nanovolt-resolution DC constant voltage source, suitable for calibration of weak signal measurement systems.
Tags: 10nV Resolution, Ultra-low Noise, 0.002% Stability
| Output Range | 0.1mV ~ 25mV |
| Output Resolution | 10nV |
| Short-term Stability | 0.002% (24h) |
| Adjustment Fineness | 0.1ppm |
Model: 1101A
7½-digit ultra-precision weak voltage measurement instrument with extremely low noise, high input impedance, and dual-channel differential input.
Tags: 7½-digit, 9.2nV Noise, Dual-channel Differential
| Resolution | 7½ digits |
| Measurement Accuracy | Better than 0.003% |
| Noise Performance (10mV range) | Single-ended 9.2 nV p-p |
| Input Resistance | 10GΩ |
| Communication Interface | LAN + USB |
Model: 1401A
Decimal knob control, achieving precise ratio output from 0.0001% to 111.111%.
Tags: 0.005% Error, Decimal Knob, Wide Ratio Range
| Adjustment Mode | Decimal knob switch control |
| Output Ratio Range | 0.0001% ~ 111.111% |
| Max Permissible Error | 0.005% |
Model: SG61x
Portable smart process calibrator, supports HART protocol, easy to operate.
Tags: HART Protocol, 0.01 Class Accuracy, Portable Design
| Accuracy Class | 0.01 Class / 0.02 Class |
| Voltage Output Range | -12.00000V ~ 30.0000V |
| Current Output Range | 0.0000mA ~ 30.0000mA |
| HART Function | Supports DVC6200 auto-tuning (SG61xH model) |
Model: 4102A
Dual-channel platinum resistance measurement, supports ITS-90 temperature scale conversion and reverse current switching technology.
Tags: 4mK Accuracy, Reverse Current Switching, PT25/100/1000
| Measurement Range | Temp: -200℃ ~ +800℃ |
| Resolution | Temp: 0.01mK (Pt100) |
| Measurement Accuracy | Temp: 4mK/6mK/8mK |
| Sensor Type | PT25, PT100, PT1000 |
| Data Interface | USB / Bluetooth |
Model: 4101A
Up to 10 isolated universal inputs, scans 10 channels per second, supports four operating modes.
Tags: 10 Channels/sec, 4ppm Accuracy, Multi-mode
| Resistance Measurement Range | 0 Ω ~ 500 kΩ |
| Temperature Measurement Accuracy | ±0.000015 ℃ (SPRT) |
| Sampling Rate | Fastest 1 sec/time |
| Communication Interface | RS-232, Bluetooth, USB, LAN |
Model: SG186
Accuracy 1mK/5ppm, battery life over 72 hours.
Tags: 1mK Accuracy, >72h Battery Life, Handheld Portable
| Temperature Measurement Range | -200℃ ~ +800℃ (Pt100) |
| Temperature Accuracy | 1mK (Pt25/Pt100/Pt1000) |
| Channel Count | 2 channels, 4-wire system |
| Measurement Time | 0.3 seconds (fastest) |
| Communication Interface | USB Type-C, supports SCPI protocol |
Model: SG671
Military-grade high-stability voltage signal source with ±0.0002pH ultra-high precision output, designed for calibration of Class 0.001 and below high-precision pH meters, ion meters, and automatic potentiometric titrators.
Tags: ±0.0002pH, Class 0.001, Portable & Efficient, High Impedance Switching
| pH Output Range | -3.0000 ~ 17.0000 pH |
| pH Permissible Error | ±0.0002 pH |
| pX Output Range | -3.0000 ~ 17.0000 pX |
| pX Permissible Error | ±0.0003 pX |
| mV Output Range | -2000.000 ~ 2000.000 mV |
| mV Permissible Error | ±0.002% FS |
| Equivalent Output Resistance | <100 Ω |
| High Impedance Switching | 0G / 1G / 3G |
| Temperature Compensation | 0.00 ~ 99.99 ℃ |
| Battery Life | >16 hours |
| Weight | 0.7 kg |
| Dimensions | 197×103×55 mm |